
HZDP-80KV 80kV trè ba frekans VLF AC Hipot tèsteur
80kV trè ba frekans VLF AC Hipot tèsteur
VLF AC Hipot Tester CE Sètifikasyon

Modèl non | Rated Voltage | Chaj pote Kapasite | Pouvwa FuseTube | Estrikti pwodwi |
HZDP-30 | 30kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 10A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF | ||||
HZDP-40 | 40kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 10A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF | ||||
HZDP-50 | 50kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 20A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF | ||||
HZDP-60 | 60kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 20A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF | ||||
HZDP-80 | 80kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 20A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF | ||||
HZDP-90 | 90kV (Peak) | 0.1Hz, Less than or equal to 1.1µF | 20A | Kontwolè Booster |
0.05Hz, Less than or equal to 2.2µF | ||||
0.02Hz, Less than or equal to 5.5µF |





VLF AC Hipot tèsteur pwodwi brèf
VLF AC Hipot Tester la konbine modèn teknoloji avanse dijital frekans varyab ak kontwòl mikwo òdinatè ansanm, kidonk, li ka reyalize plen otomatik ogmantasyon vòltaj la, stepdown, mezi ak pwoteksyon kòm byen ke entèvansyon manyèl la nan pwosesis la nan ogmantasyon vòltaj otomatik. Konsepsyon elektwonik konplè a asire ti gwosè a ak pwa limyè. Gwo ekran LCD a asire ekspozisyon klè ak vizyèl, epi li ka montre fòm vag pwodiksyon an. Aparèy pou enprime a bay rapò tès yo.

VLF AC Hipot Tester paramèt teknik
1. Evalyasyon vòltaj pwodiksyon: Gade detay nan Tablo 1
2. Frekans pwodiksyon: 0.1Hz, 0.05Hz, 0.02Hz
3. jistès mezi: 3 pousan
4. Positive and negative voltage peak errors: Less than or equal to 3%
5. Voltage wave form distortion: Less than or equal to 5%
6. Use condition: indoor and outdoor; temperature: -10 degree ∽ plus 40 degree
Humidity: Less than or equal to 85%RH
7. Power: AC50Hz, 220V ±5 percent
8. Tib fuse ekipman pou pouvwa: Gade detay nan Tablo 1



Baj popilè: HZDP-80KV 80kV Trè Ba Frekans VLF AC Hipot tèsteur, Lachin, Swèd, manifaktirè, pri, pou vann, VLF Hipot tèsteur, pri vlf ac hipot tèsteur, vlf hipot tès seri, 80 KV VLF Hipot, ac dc vlf hipot, trè ba frekans AC ipotèk tès HZDP-80KV, vlf 70kv, vlf hv hipot tèsteur 90kV, hipot teste, vlf hv ipotèk tèsteur
Voye rechèch
